AEM electrolysis after 1,000 hours: what a stable voltage can—and cannot—tell us

A durability claim becomes useful when it explains what was tested, how performance changed and what remained inside the device afterwards. For hydrogen technology buyers, “1,000 hours” should be the beginning of that discussion.

Walerian Majewski ·

Generated artistic impression of nickel felt fibres, inspired by electron microscopy images. AI generated.
Image: Generated artistic impression of nickel felt fibres, inspired by electron microscopy images. AI generated.

A study by Feng Guo and colleagues, published in Catalysts on 21 November 2026, compared four nickel-felt-supported anodes. Their ranking in half-cell screening did not fully match their ranking in assembled anion-exchange membrane water electrolysis cells. The NiFeCoMo formulation performed best in the device comparison. Read the study.

The durability experiment used a 1 cm² cell, a platinum/carbon cathode and a commercial membrane, operating at 65°C with 1 M KOH. At 1 A/cm², pre- and post-test measurements showed voltage rising from 1.679 to 1.729 V. Separately, the operating trace yielded a fitted drift of approximately 12 µV/h. Unplanned power interruptions occurred; transient readings immediately after restart were excluded from that fit.

These are different measurements. The fitted slope should not be multiplied by the test duration and presented as equivalent to the before-and-after voltage change.

Post-test analysis found molybdenum below the detection limit in the recovered anode. However, whole-electrode sampling could not establish when it changed, where it went or its causal role. Catalyst loading was not independently measured.

For developers, these findings raise two separate engineering questions: can the device continue delivering acceptable performance, and can its materials evolve predictably enough to support reliable operation? A changing composition is not, by itself, a commercial failure. It becomes a concern when its consequences cannot be controlled, reproduced or incorporated into maintenance and lifetime expectations.

The distinction also matters when comparing suppliers. A purchase decision needs evidence relevant to the proposed operating duty. A laboratory result cannot establish how a larger stack will respond to uneven flow, repeated shutdowns, manufacturing variation or years of service. Those are separate validation tasks.

The reported voltage is also insufficient to calculate the cost of hydrogen. Such a calculation would require measured hydrogen output, operating availability, auxiliary electricity consumption and replacement assumptions. Assigning a cost advantage from this experiment alone would go beyond the evidence.

For project teams reviewing AEM technology, three questions are particularly useful:

  • Does the test represent our intended temperature, feed chemistry and operating profile?

  • Are startup behaviour, interruptions and data exclusions documented?

  • Is the performance evidence accompanied by material analysis and repeat testing?

The practical value of this research is that it encourages a more complete conversation about durability. When requesting evidence from an electrolyser supplier, ask for the operating history and the condition of the recovered components alongside the headline number of hours.